INDUSTRIAL PRODUCT
CT Scan Machine Plastic Patient Table Top Cover Mould and Moulding Service
₹1,300.00
CT Scan Machine Plastic Patient Table Top Cover Mould and Moulding Service | Renovator Appliances Ltd
Product Overview
Renovator Appliances Ltd manufactures precision Plastic Injection Moulds and provides injection moulding solutions for CT Scan Machine Plastic Patient Table Top Cover components used in CT scanner patient table assemblies. The patient table top cover is a moulded plastic surface component designed to provide a smooth, finished, and protective covering over the patient table structure while supporting the required patient positioning and movement interface.
The mould is developed according to the table-top dimensions, length and width, edge profile, surface contour, patient-support requirements, mounting arrangement, underlying table structure, and required clearance from moving components. The cover can be customized with locating features, mounting bosses, clips, retaining edges, cable or mechanism clearances, and other equipment-specific details.
Key Features
Precision injection moulding for CT scanner patient table top covers
Customized table-top dimensions and profile
Smooth patient-facing external surface
Designed according to the underlying table structure
Accurate fitment with adjoining table components
Controlled wall thickness for dimensional stability
Reinforced mounting areas where required
Integrated locating features and retaining edges
Screw, clip, or snap-fit mounting options
Clearance for table movement mechanisms
Smooth edges for patient-contact areas
Customized colour, texture, and surface finish
Suitable for prototype and volume production
OEM and ODM manufacturing support
Industrial Applications
| Application | Use of CT Scan Machine Plastic Patient Table Top Cover |
|---|---|
| CT Scan Machine | Provides a finished surface over the patient table assembly |
| CT Patient Table | Covers the underlying structural table section |
| Diagnostic CT Equipment | Supports the patient-positioning interface |
| Medical Imaging Equipment | Provides a smooth and cleanable external table surface |
| Patient Support Assembly | Integrates with the table structure and movement system |
| CT Table Enclosure | Provides protection and finished external appearance |
| OEM CT Systems | Manufactured according to customized table designs |
Manufacturing Process
1. Product Design & Development
The CT Scan Machine Plastic Patient Table Top Cover is developed according to the customer's CAD drawing, 3D model, physical sample, table dimensions, or complete patient table assembly. The design is reviewed for overall length and width, surface contour, edge profile, mounting arrangement, underlying structure, movement clearance, and patient-contact requirements.
Particular attention is given to the cover's surface profile and dimensional stability so that it remains properly aligned with the table structure during normal positioning and movement.
2. Plastic Mould Design
The injection mould is designed around the complete table-top cover geometry, including the patient-facing surface, edge profile, mounting bosses, locating features, retaining lips, clips, snap-fits, and required mechanism-clearance areas.
Because patient table top covers can have relatively large surface areas, mould filling, cooling balance, shrinkage, draft angles, parting lines, gate locations, and ejection arrangements are carefully considered to minimize warpage, bowing, twisting, and sink marks.
3. Mould Manufacturing
Mould components are manufactured using suitable mould steels such as P20 Steel, H13 Steel, or S136 Steel, depending on production quantity, selected plastic material, mould-life requirements, component complexity, and surface-finish requirements.
CNC machining, EDM, grinding, polishing, precision fitting, and mould assembly are used to achieve accurate cavity and core geometry.
4. Injection Moulding
The selected plastic material is processed under controlled injection moulding conditions. Injection temperature, filling speed, pressure, holding pressure, cooling time, and cycle parameters are adjusted according to the selected plastic grade and table-top cover geometry.
Controlled processing helps maintain the required surface profile, flatness, dimensions, edge geometry, mounting accuracy, and repeatable fitment with the patient table.
5. Finishing & Assembly Preparation
After moulding, the patient table top covers are inspected for flash, gate marks, sink marks, short shots, warpage, surface imperfections, and sharp edges. Gate trimming and edge finishing are performed where required.
The component can be prepared for surface texturing, painting, printing, labelling, or installation with the corresponding patient table structure and adjoining covers.
6. Quality Inspection
Finished CT Scan Machine Plastic Patient Table Top Cover components are checked for overall dimensions, surface profile, edge geometry, mounting features, internal clearance, surface finish, and fitment with the patient table assembly.
Trial assembly can be performed to verify alignment, movement clearance, adjoining-cover fitment, surface continuity, and proper seating on the table structure.
Raw Materials
| Material | Suitability for CT Scan Machine Plastic Patient Table Top Cover |
|---|---|
| ABS | Suitable for rigid table covers requiring good surface appearance and dimensional stability |
| PC+ABS | Suitable where improved impact resistance and dimensional performance are required |
| PC | Suitable where higher impact and thermal performance are required |
| PP | Lightweight option for suitable table-cover applications |
| HIPS | Suitable for selected rigid and cost-sensitive enclosure applications |
| PBT | Suitable where dimensional stability and mechanical performance are important |
| Flame-Retardant ABS | Suitable where specified flame-performance requirements apply |
| Flame-Retardant PC+ABS | Suitable where enhanced flame-performance characteristics are required |
| Engineering-Grade Plastic | Suitable for demanding mechanical, dimensional, thermal, or environmental requirements |
The final plastic grade should be selected according to required load, impact exposure, operating temperature, cleaning and disinfectant conditions, surface requirements, dimensional stability, flame-performance requirements, and applicable medical-equipment specifications.
Quality Control
Renovator Appliances Ltd performs quality checks throughout mould development and injection moulding production. Inspection can include:
Plastic material and grade verification
Mould cavity dimensional inspection
Overall table-top dimensions
Length and width accuracy
Surface profile and contour inspection
Edge-profile dimensions
Wall-thickness consistency
Mounting-hole and boss positions
Locating-feature accuracy
Retaining-edge dimensions
Clip and snap-fit accuracy
Under-table mechanism clearance
Adjoining-component clearance
Flatness inspection
Warpage and deformation inspection
Bowing and twisting inspection
Sink-mark inspection
Short-shot inspection
Flash and burr inspection
Surface-finish inspection
Colour consistency
Table assembly fitment
Movement-clearance inspection
Trial assembly inspection
Batch-to-batch dimensional consistency
Buyer Guide
When ordering a CT Scan Machine Plastic Patient Table Top Cover Mould and Moulding Service, buyers should provide a CAD drawing, 3D model, physical sample, patient-table specification, or complete table assembly. Important requirements include:
Table-top length and width
Overall cover thickness
Surface profile and contour
Edge profile
Patient-contact surface requirements
Underlying table structure dimensions
Mounting locations
Screw, clip, or snap-fit requirements
Locating-feature requirements
Retaining-edge requirements
Clearance from moving mechanisms
Clearance from adjoining components
Required wall thickness
Surface texture and finish
Cleaning and disinfectant requirements
Colour requirements
Expected mechanical load
Operating temperature
Plastic material and grade
Flame-performance requirements where applicable
Expected production quantity
Required mould life
Prototype requirements
Mass-production requirements
OEM or ODM assembly requirements
For CT scanner equipment, the patient table top cover should be validated as part of the complete medical-device assembly for mechanical fitment, patient-support and movement requirements, load conditions, surface safety, cleaning and disinfectant compatibility, thermal conditions, EMC considerations, imaging-related clearances, radiation safety, and applicable regulatory requirements. The plastic table top cover should not be assumed to provide radiation shielding or define the X-ray beam unless specifically engineered, tested, and validated for that purpose.
Why Choose Renovator Appliances Ltd?
Advanced Injection Moulding Facility
Renovator Appliances Ltd provides controlled plastic injection moulding for precision CT scanner patient table covers, panels, trims, housings, and enclosure components.
In-House Mould Manufacturing
In-house mould manufacturing provides control over large table-cover geometry, surface profile, mounting features, cooling, ejection, and surface-finish requirements.
OEM & ODM Manufacturing
Customized CT Scan Machine Plastic Patient Table Top Cover moulds and moulded components can be developed according to customer drawings, samples, patient-table specifications, and CT system designs.
Quality Assurance
Dimensional, visual, material, surface, load-related, movement-clearance, and assembly checks help maintain consistent patient table cover quality.
Cost-Effective Manufacturing
Integrated mould manufacturing and injection moulding support prototype development, development batches, and regular production quantities.
Frequently Asked Questions
1. What is a CT Scan Machine Plastic Patient Table Top Cover?
A CT Scan Machine Plastic Patient Table Top Cover is a moulded plastic component designed to provide a finished, smooth, and protective surface over the patient table structure of CT scanner equipment.
2. Can the table top cover be customized for a specific CT patient table?
Yes. The length, width, surface profile, edge geometry, mounting features, retaining structure, and mechanism clearances can be customized according to the patient table design.
3. Can the cover support the required patient-table load?
The cover can be designed according to the specified load and supported by appropriate underlying structural components. The complete table assembly should be validated for its required patient-support load and movement conditions.
4. Which plastic materials can be used for the patient table top cover?
ABS, PC+ABS, PC, PP, HIPS, PBT, flame-retardant ABS, flame-retardant PC+ABS, and suitable engineering plastics can be considered according to mechanical, thermal, dimensional, cleaning, surface, and regulatory requirements.
5. Can Renovator manufacture both the mould and patient table top cover?
Yes. Renovator Appliances Ltd can provide mould manufacturing and injection moulding solutions for customized CT Scan Machine Plastic Patient Table Top Cover production, supporting OEM and ODM requirements.
- SKU
- REN-1E6E5BD09F7A81589FE9D292