R. Industrial Supply PRODUCTS · PARTS · OEM

INDUSTRIAL PRODUCT

CT Scan Machine Plastic Patient Table Top Cover Mould and Moulding Service

SKU: REN-1E6E5BD09F7A81589FE9D292 Model: CSMPPTTC

₹1,300.00

CT Scan Machine Plastic Patient Table Top Cover Mould and Moulding Service | Renovator Appliances Ltd

Product Overview

Renovator Appliances Ltd manufactures precision Plastic Injection Moulds and provides injection moulding solutions for CT Scan Machine Plastic Patient Table Top Cover components used in CT scanner patient table assemblies. The patient table top cover is a moulded plastic surface component designed to provide a smooth, finished, and protective covering over the patient table structure while supporting the required patient positioning and movement interface.

The mould is developed according to the table-top dimensions, length and width, edge profile, surface contour, patient-support requirements, mounting arrangement, underlying table structure, and required clearance from moving components. The cover can be customized with locating features, mounting bosses, clips, retaining edges, cable or mechanism clearances, and other equipment-specific details.

Key Features

  • Precision injection moulding for CT scanner patient table top covers

  • Customized table-top dimensions and profile

  • Smooth patient-facing external surface

  • Designed according to the underlying table structure

  • Accurate fitment with adjoining table components

  • Controlled wall thickness for dimensional stability

  • Reinforced mounting areas where required

  • Integrated locating features and retaining edges

  • Screw, clip, or snap-fit mounting options

  • Clearance for table movement mechanisms

  • Smooth edges for patient-contact areas

  • Customized colour, texture, and surface finish

  • Suitable for prototype and volume production

  • OEM and ODM manufacturing support

Industrial Applications

ApplicationUse of CT Scan Machine Plastic Patient Table Top Cover
CT Scan MachineProvides a finished surface over the patient table assembly
CT Patient TableCovers the underlying structural table section
Diagnostic CT EquipmentSupports the patient-positioning interface
Medical Imaging EquipmentProvides a smooth and cleanable external table surface
Patient Support AssemblyIntegrates with the table structure and movement system
CT Table EnclosureProvides protection and finished external appearance
OEM CT SystemsManufactured according to customized table designs

Manufacturing Process

1. Product Design & Development

The CT Scan Machine Plastic Patient Table Top Cover is developed according to the customer's CAD drawing, 3D model, physical sample, table dimensions, or complete patient table assembly. The design is reviewed for overall length and width, surface contour, edge profile, mounting arrangement, underlying structure, movement clearance, and patient-contact requirements.

Particular attention is given to the cover's surface profile and dimensional stability so that it remains properly aligned with the table structure during normal positioning and movement.

2. Plastic Mould Design

The injection mould is designed around the complete table-top cover geometry, including the patient-facing surface, edge profile, mounting bosses, locating features, retaining lips, clips, snap-fits, and required mechanism-clearance areas.

Because patient table top covers can have relatively large surface areas, mould filling, cooling balance, shrinkage, draft angles, parting lines, gate locations, and ejection arrangements are carefully considered to minimize warpage, bowing, twisting, and sink marks.

3. Mould Manufacturing

Mould components are manufactured using suitable mould steels such as P20 Steel, H13 Steel, or S136 Steel, depending on production quantity, selected plastic material, mould-life requirements, component complexity, and surface-finish requirements.

CNC machining, EDM, grinding, polishing, precision fitting, and mould assembly are used to achieve accurate cavity and core geometry.

4. Injection Moulding

The selected plastic material is processed under controlled injection moulding conditions. Injection temperature, filling speed, pressure, holding pressure, cooling time, and cycle parameters are adjusted according to the selected plastic grade and table-top cover geometry.

Controlled processing helps maintain the required surface profile, flatness, dimensions, edge geometry, mounting accuracy, and repeatable fitment with the patient table.

5. Finishing & Assembly Preparation

After moulding, the patient table top covers are inspected for flash, gate marks, sink marks, short shots, warpage, surface imperfections, and sharp edges. Gate trimming and edge finishing are performed where required.

The component can be prepared for surface texturing, painting, printing, labelling, or installation with the corresponding patient table structure and adjoining covers.

6. Quality Inspection

Finished CT Scan Machine Plastic Patient Table Top Cover components are checked for overall dimensions, surface profile, edge geometry, mounting features, internal clearance, surface finish, and fitment with the patient table assembly.

Trial assembly can be performed to verify alignment, movement clearance, adjoining-cover fitment, surface continuity, and proper seating on the table structure.

Raw Materials

MaterialSuitability for CT Scan Machine Plastic Patient Table Top Cover
ABSSuitable for rigid table covers requiring good surface appearance and dimensional stability
PC+ABSSuitable where improved impact resistance and dimensional performance are required
PCSuitable where higher impact and thermal performance are required
PPLightweight option for suitable table-cover applications
HIPSSuitable for selected rigid and cost-sensitive enclosure applications
PBTSuitable where dimensional stability and mechanical performance are important
Flame-Retardant ABSSuitable where specified flame-performance requirements apply
Flame-Retardant PC+ABSSuitable where enhanced flame-performance characteristics are required
Engineering-Grade PlasticSuitable for demanding mechanical, dimensional, thermal, or environmental requirements

The final plastic grade should be selected according to required load, impact exposure, operating temperature, cleaning and disinfectant conditions, surface requirements, dimensional stability, flame-performance requirements, and applicable medical-equipment specifications.

Quality Control

Renovator Appliances Ltd performs quality checks throughout mould development and injection moulding production. Inspection can include:

  • Plastic material and grade verification

  • Mould cavity dimensional inspection

  • Overall table-top dimensions

  • Length and width accuracy

  • Surface profile and contour inspection

  • Edge-profile dimensions

  • Wall-thickness consistency

  • Mounting-hole and boss positions

  • Locating-feature accuracy

  • Retaining-edge dimensions

  • Clip and snap-fit accuracy

  • Under-table mechanism clearance

  • Adjoining-component clearance

  • Flatness inspection

  • Warpage and deformation inspection

  • Bowing and twisting inspection

  • Sink-mark inspection

  • Short-shot inspection

  • Flash and burr inspection

  • Surface-finish inspection

  • Colour consistency

  • Table assembly fitment

  • Movement-clearance inspection

  • Trial assembly inspection

  • Batch-to-batch dimensional consistency

Buyer Guide

When ordering a CT Scan Machine Plastic Patient Table Top Cover Mould and Moulding Service, buyers should provide a CAD drawing, 3D model, physical sample, patient-table specification, or complete table assembly. Important requirements include:

  • Table-top length and width

  • Overall cover thickness

  • Surface profile and contour

  • Edge profile

  • Patient-contact surface requirements

  • Underlying table structure dimensions

  • Mounting locations

  • Screw, clip, or snap-fit requirements

  • Locating-feature requirements

  • Retaining-edge requirements

  • Clearance from moving mechanisms

  • Clearance from adjoining components

  • Required wall thickness

  • Surface texture and finish

  • Cleaning and disinfectant requirements

  • Colour requirements

  • Expected mechanical load

  • Operating temperature

  • Plastic material and grade

  • Flame-performance requirements where applicable

  • Expected production quantity

  • Required mould life

  • Prototype requirements

  • Mass-production requirements

  • OEM or ODM assembly requirements

For CT scanner equipment, the patient table top cover should be validated as part of the complete medical-device assembly for mechanical fitment, patient-support and movement requirements, load conditions, surface safety, cleaning and disinfectant compatibility, thermal conditions, EMC considerations, imaging-related clearances, radiation safety, and applicable regulatory requirements. The plastic table top cover should not be assumed to provide radiation shielding or define the X-ray beam unless specifically engineered, tested, and validated for that purpose.

Why Choose Renovator Appliances Ltd?

Advanced Injection Moulding Facility

Renovator Appliances Ltd provides controlled plastic injection moulding for precision CT scanner patient table covers, panels, trims, housings, and enclosure components.

In-House Mould Manufacturing

In-house mould manufacturing provides control over large table-cover geometry, surface profile, mounting features, cooling, ejection, and surface-finish requirements.

OEM & ODM Manufacturing

Customized CT Scan Machine Plastic Patient Table Top Cover moulds and moulded components can be developed according to customer drawings, samples, patient-table specifications, and CT system designs.

Quality Assurance

Dimensional, visual, material, surface, load-related, movement-clearance, and assembly checks help maintain consistent patient table cover quality.

Cost-Effective Manufacturing

Integrated mould manufacturing and injection moulding support prototype development, development batches, and regular production quantities.

Frequently Asked Questions

1. What is a CT Scan Machine Plastic Patient Table Top Cover?

A CT Scan Machine Plastic Patient Table Top Cover is a moulded plastic component designed to provide a finished, smooth, and protective surface over the patient table structure of CT scanner equipment.

2. Can the table top cover be customized for a specific CT patient table?

Yes. The length, width, surface profile, edge geometry, mounting features, retaining structure, and mechanism clearances can be customized according to the patient table design.

3. Can the cover support the required patient-table load?

The cover can be designed according to the specified load and supported by appropriate underlying structural components. The complete table assembly should be validated for its required patient-support load and movement conditions.

4. Which plastic materials can be used for the patient table top cover?

ABS, PC+ABS, PC, PP, HIPS, PBT, flame-retardant ABS, flame-retardant PC+ABS, and suitable engineering plastics can be considered according to mechanical, thermal, dimensional, cleaning, surface, and regulatory requirements.

5. Can Renovator manufacture both the mould and patient table top cover?

Yes. Renovator Appliances Ltd can provide mould manufacturing and injection moulding solutions for customized CT Scan Machine Plastic Patient Table Top Cover production, supporting OEM and ODM requirements.

Product informationSpecifications shown below
Industrial catalogProduct details for business buyers
SKU
REN-1E6E5BD09F7A81589FE9D292

Browse product categories