R. Industrial Supply PRODUCTS · PARTS · OEM

INDUSTRIAL PRODUCT

X-Ray Machine Plastic Collimator Shutter Housing Mould and Moulding Service

SKU: REN-1D9B2E951A1C242929E001B5 Model: XMPCSH

₹600.00

X-Ray Machine Plastic Collimator Shutter Housing Mould and Moulding Service | Renovator Appliances Ltd

Product Overview

Renovator Appliances Ltd manufactures X-Ray Machine Plastic Collimator Shutter Housings using precision Plastic Injection Moulding and custom mould manufacturing processes. The shutter housing is a structural plastic enclosure component designed to support and protect the collimator shutter mechanism within the tube head or collimator assembly.

The housing is developed around the required shutter travel path, mounting interfaces, guide features, actuator or linkage clearances, and surrounding collimator structure. Accurate moulding of the housing geometry is important for maintaining correct shutter alignment and smooth mechanical movement.

The plastic housing itself should not be assumed to provide radiation shielding or define the X-ray beam unless specifically engineered, tested, and validated for those functions.

Key Features

  • Application-specific shutter housing geometry

  • Accurate shutter mechanism clearance

  • Precision mounting and locating features

  • Guided internal movement area

  • Controlled wall thickness

  • Reinforced mounting points

  • Actuator and linkage clearance

  • Smooth internal guide surfaces

  • Accurate interface with the collimator assembly

  • Consistent dimensional stability

  • Customizable according to tube head design

  • Suitable for OEM and high-volume production

Industrial Applications

Application AreaComponent Function
X-Ray Tube Head AssemblySupports and encloses the collimator shutter mechanism
Diagnostic X-Ray EquipmentProvides structural support around shutter components
Collimator AssemblyMaintains the required mechanical interface for shutter movement
Mobile X-Ray MachinesProvides a lightweight moulded shutter housing
Fixed X-Ray SystemsIntegrates the shutter mechanism with the tube head
OEM X-Ray EquipmentCustomized housing for specific collimator designs

Manufacturing Process

1. Product Design & Development

The shutter housing is developed according to the complete collimator mechanism. Important parameters include shutter dimensions, travel direction, guide clearances, actuator or linkage interface, mounting locations, internal component clearance, and mating geometry with the tube head or collimator body.

The housing geometry is coordinated with the shutter mechanism so that the plastic structure does not obstruct the specified movement or beam path. Any radiation-shielding function must be separately engineered and validated rather than assumed from the plastic housing.

2. Plastic Mould Design

The mould is designed to reproduce the housing profile, internal guides, mounting bosses, locating features, actuator openings, ribs, and fastening interfaces accurately. Core and cavity geometry is optimized for dimensional stability and smooth shutter clearance, while draft, parting-line placement, gate location, cooling, shrinkage allowance, and ejection are considered to minimize warpage.

3. Mould Manufacturing

The mould is manufactured using precision machining and mould-making processes. P20, H13, S136, or another suitable mould steel can be selected according to production volume, plastic material, surface-finish requirements, and expected mould life. Critical guide, mounting, and interface dimensions are inspected before mould trials.

4. Injection Moulding

The selected plastic material is injection moulded under controlled processing conditions. Injection pressure, injection speed, melt temperature, holding pressure, and cooling time are adjusted according to the selected material and housing geometry. Controlled filling and cooling help maintain guide clearances, mounting dimensions, and overall housing alignment.

5. Finishing & Assembly Preparation

After moulding, gates, runners, flash, and excess material are removed. Internal guide areas, shutter clearances, actuator openings, and mounting interfaces are inspected for flash or obstructions. Surfaces that interact with moving components are checked for smoothness before assembly.

6. Quality Inspection

Finished shutter housings are inspected for overall dimensions, internal clearances, guide geometry, mounting-hole positions, boss dimensions, locating features, wall thickness, flatness, warpage, surface finish, and flash. Trial assembly with the specified shutter and actuator mechanism verifies fit, movement clearance, and alignment.

Raw Materials

Material / ComponentTypical Selection Consideration
ABSSuitable for rigid structural enclosure components
PC+ABSConsidered where improved impact resistance and dimensional stability are required
PCSuitable where higher impact performance is required
PBTConsidered where dimensional stability and mechanical performance are important
Flame-Retardant ABSConsidered where enclosure specifications require flame-retardant properties
Flame-Retardant PC+ABSSuitable where specified flame-retardant and mechanical properties are required
Engineering PlasticSelected according to mechanical, thermal, dimensional, and equipment requirements
P20 SteelSuitable for general-purpose production moulds
H13 SteelSuitable for demanding production conditions
S136 SteelSuitable where corrosion resistance and high-quality mould surfaces are required

Quality Control

Renovator Appliances Ltd applies dimensional, visual, and functional inspections throughout shutter-housing production. Key inspection areas include:

  • Overall housing dimensions

  • Shutter cavity dimensions

  • Guide-channel dimensions

  • Shutter travel clearance

  • Mounting-hole position

  • Mounting-boss dimensions

  • Locating-feature accuracy

  • Actuator and linkage clearance

  • Wall thickness

  • Flatness

  • Warpage

  • Internal surface finish

  • Flash and burr inspection

  • Sink marks and moulding defects

  • Shutter fitment

  • Movement clearance

  • Collimator assembly fitment

  • Material compliance with specified requirements

Buyer Guide

When sourcing an X-Ray Machine Plastic Collimator Shutter Housing, buyers should provide the CAD model or engineering drawing, shutter dimensions, travel distance, guide geometry, actuator or linkage details, mounting locations, tube-head interface dimensions, required clearances, plastic material specification, and production quantity.

The housing should be evaluated together with the complete shutter mechanism because guide clearances, mounting accuracy, actuator alignment, and shutter travel directly affect mechanical operation.

The plastic housing should not be treated as an X-ray radiation-shielding component unless its material, geometry, thickness, and complete assembly have been specifically engineered and validated for that purpose. Final equipment validation should follow applicable medical-device, electrical, mechanical, radiation-safety, and regulatory requirements.

Why Choose Renovator Appliances Ltd?

Advanced Injection Moulding Facility

We provide controlled Plastic Injection Moulding for producing precision shutter housings with consistent guide geometry, mounting interfaces, and dimensional stability.

In-House Mould Manufacturing

Our mould manufacturing capabilities support internal guide features, actuator clearances, mounting bosses, locating elements, ribs, and detailed collimator interfaces.

OEM & ODM Manufacturing

We support OEM and ODM requirements from component development and mould design through mould manufacturing, injection moulding, inspection, and production supply.

Quality Assurance

Critical housing dimensions, shutter clearances, guide geometry, mounting features, surface finish, warpage, and assembly fitment are inspected according to customer specifications.

Cost-Effective Manufacturing

Optimized mould construction, suitable engineering plastics, and controlled injection moulding processes support efficient production of repeatable collimator shutter housings.

Frequently Asked Questions

1. What is an X-Ray Machine Plastic Collimator Shutter Housing?

It is a moulded plastic structural housing that supports and encloses the mechanical shutter components within an X-ray collimator assembly.

2. Does the plastic shutter housing provide radiation shielding?

Not automatically. A standard plastic housing should not be considered radiation shielding unless it has been specifically engineered, tested, and validated for that function.

3. Which plastics can be used for the shutter housing?

ABS, PC+ABS, PC, PBT, and specified flame-retardant engineering plastics can be considered according to mechanical load, temperature, dimensional stability, electrical requirements, and equipment specifications.

4. Can the housing be customized for a specific shutter mechanism?

Yes. The housing can be developed according to the customer's CAD model or engineering drawing, including shutter guides, travel clearances, mounting interfaces, actuator openings, and tube-head mating features.

5. Can Renovator Appliances Ltd manufacture both the mould and shutter housing?

Yes. Renovator Appliances Ltd can provide the complete service from component development and mould design to mould manufacturing, Plastic Injection Moulding, quality inspection, and OEM/ODM production.

Product informationSpecifications shown below
Industrial catalogProduct details for business buyers
SKU
REN-1D9B2E951A1C242929E001B5

Browse product categories